Application of Oxygen Analyzers in Pressure Vacuum Ovens

Release time:

2025-10-28

Author:

Source:


Summary

The OXY-GC-168 oxygen analyzer uses a series of steps and key points to ensure accurate and reliable measurement results when monitoring oxygen levels in pressure vacuum ovens. The following are specific monitoring methods and precautions:

During the semiconductor chip packaging process, encapsulant materials can absorb moisture or generate volatile substances, creating cavities (bubbles) during the process. During the reflow process, the moisture and cavities expand instantly due to heat, causing significant stress on the chip and package itself, potentially leading to IC failure. While these stresses do not necessarily lead to immediate IC failure, they can seriously impact product reliability and quality. Pressure ovens can effectively address issues encountered during IC packaging, flip-chip, bumping foundry, wafer assembly, and panel manufacturing. Oxygen, due to its oxidizing properties, accelerates these adverse reactions. Oxygen is also a key indicator of pressure, making monitoring oxygen levels in pressure vacuum ovens crucial.

The OXY-GC-168 oxygen analyzer uses a series of steps and key points to ensure accurate and reliable measurement results when monitoring oxygen levels in pressure vacuum ovens. The following are specific monitoring methods and precautions:

1. Installation Location

Select an appropriate location: Install the OXY-GC-168 oxygen analyzer at the pressure vacuum oven's gas outlet or at a dedicated sampling point, ensuring the sensor has direct and accurate access to the oven's gas. This ensures that the measured oxygen content truly reflects the conditions inside the oven.

Installation Requirements: Follow the analyzer's installation manual to ensure a secure installation and leak-free connections between the sensor and the sampling point.

2. Calibration

Pre-calibration Preparation: Before installation, thoroughly calibrate the oxygen analyzer, including zero and span calibration. This ensures accurate and reliable measurement results.

3. Setting Alarm Thresholds

Threshold Setting: Set alarm thresholds for the OXY-GC-168 oxygen analyzer on the control system interface. When oxygen levels exceed or fall below these preset values, the system should trigger an alarm, notifying the operator to take timely action.

Threshold Adjustment: Set and adjust the alarm thresholds appropriately based on the pressure vacuum oven's process requirements and product characteristics.

4.Real-Time Monitoring and Data Analysis

Real-Time Monitoring: During oven operation, the OXY-GC-168 oxygen analyzer monitors the oxygen content in the oven in real time and transmits the data to the control system.

Data Analysis: The control system automatically records historical oxygen content data and generates reports or trend charts. Operators should regularly analyze this data to understand trends and abnormalities in the oven's oxygen content.

Note: The oxygen probe has a pressure range of 0-5 atmospheres. A pressure reducing valve must be installed before the oxygen probe installation line in pressure ovens.

More Information


Metal Dome Membrane Switch Technology: Improving User Interaction in Modern Instrumentation


Metal Dome Membrane Switch suppliers provide tactile, durable switching solutions for reliable control panels and electronic instruments

2026-10-21

Focus on Western Biomanufacturing | Shanghai Gaochuan Makes Appearance at the 2026 Xi'an Biopharmaceutical and Technology Equipment Exhibition


The 2026 Xi'an Biopharmaceutical & Technical Equipment Exhibition, along with the Xi'an Chemical Technology & Equipment Exhibition, grandly opened at the Xi'an International Convention and Exhibition Center, running for three days from October 15 to 17.

2026-10-16